Option
Function
[105] Set vir. mas.
pos. to actual
N O T I C E
This option is only available with software version 48.XX.
Signal for setting virtual master position = actual follower position. This is needed for setting the cor-
rect starting position for position-controlled virtual master ensuring that the virtual master position is
aligned with the physical position of the follower.
[106] Set master
home
N O T I C E
This option is only available with software version 48.XX.
Sets the actual master position to the value of
parameter 17-88 Master Home Position
.
[107] Target inverse
N O T I C E
This option is only available with software version 48.XX.
Changes the sign of the set target position. For example, if the set target is 1000, the activation of this
option changes the value to -1000.
[108] Enable master
offset
N O T I C E
This option is only available with software version 48.XX.
Activates the master offset selected in
parameter 3-26 Master Offset
when
parameter 17-93 Master Offset
Selection
has a selection from
[1] Absolute
to
[5] Relative Touch Sensor
.
[109] Enable. vir.mas-
ter
N O T I C E
This option is only available with software version 48.XX.
Enable signal for the virual master function. Only applicable when option
[10] Synchronization
is selec-
ted in
parameter 1-00 Configuration Mode
.
[110] Start homing
N O T I C E
This option is only available with software version 48.XX.
Starts the homing function selected in
parameter 17-80 Homing Function
. Must remain high until hom-
ing is done, otherwise homing is aborted.
[111] Activate touch
N O T I C E
This option is only available with software version 48.XX.
Activates monitoring of the touch sensor input.
[112] Relative posi-
tion
N O T I C E
This option is only available with software version 48.XX.