Parameter 0-32 Custom Readout Max Value
.
Parameter 4-13 Motor Speed High Limit [RPM]
.
Parameter 4-14 Motor Speed High Limit [Hz]
.
Actual speed.
e
3
0
b
t1
0
5
.1
2
0
Lin
ea
r U
nit
(e
.g.
sp
ee
d a
nd
flo
w)
Q
ua
dr
at
ic
Un
it
(P
re
ssu
re
)
C
ub
ic
U
ni
t (
P
ow
er
)
Custom Readout (Value)
P 16-09
Custom Readout
Unit P 0-30
Max value
P 0-32
Min value
P 0-31
Linear
units only
Motor Speed
Motor Speed
High limit
P 4-13 (RPM)
P 4-14 (Hz)
Illustration 28: Custom Readout
The relation depends on the type of unit selected in
parameter 0-30 Custom Readout Unit
.
Table 20: Speed Relations for Different Unit Types
Unit type
Speed relation
Dimensionless
Linear
Speed
Flow, volume
Flow, mass
Velocity
Length
Temperature
Pressure
Quadratic
Power
Cubic
Parameter 0-30 Unit for User-defined Readout
Table 21: Parameter 0-30 Unit for User-defined Readout
0-30 Unit for User-defined Readout
Default value: [0] None
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
It is possible to program a value to be shown in the display of the LCP. The value has a linear, squared, or cubed relation to speed.
This relation depends on the unit type selected. The actual calculated value can be read in
parameter 16-09 Custom Readout
, and/or
shown in the display by selecting
[16-09] Custom Readout
in
parameter 0-20 Display Line 1.1 Small
to
parameter 0-24 Display Line 3
Large
.
AU275636650261en-000101 / 130R0334
50 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide