5.0 Programming For The PC Attendant Position
Use the following procedures to program the DXP Plus system to operate with the PC attendant position. Follow
these procedures in the order that this manual presents them as they provide a logical progression of the
programming.
5.1
Enabling The PC Attendant Position
Description:
Each PC attendant position requires a station port, two line ports, a serial data port, and a line
group for operation. You must identify these items through this programming action for each
PC attendant position before the equipment will function properly.
Programming:
1. Press CONTROL T for main menu.
2. From main menu, select peripherals and press ENTER.
3. From peripherals menu, select PC attendant and press ENTER.
4. Type PC attendant number (1–4) and press ENTER.
5. Type item number for station port and press ENTER, then type 1–480 for station port .
Important—disconnect any telephone that is currently installed there.
6. For line pair, type odd/even number pair that corresponds to location where cable was
connected on common equipment (for example, enter 1,2 or 15,16 or 119,120 and so forth).
Special instruction—Always type the odd line number first. Remember, the line numbers
on each line board ascend from bottom line jack (lines 1,2) to top line jack (lines 7,8),
and the line ports on the main and expansion cabinets ascend from right to left based
on the board slot (line ports 1–8, 9–17, 18–26 and so forth).
NOTE: The lines that you assign here are exclusively for PC attendant position use and cannot be used for
out-going call operations. Do not assign them for any other system use.
7. For line group, type line group number (1–16).
8. For serial port, type 1 or 2 for RS-232 port 1 or 2 on the system central processor board
where you connected the PC attendant position.
9. Press ESCAPE twice.
10. Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
11. Press ESCAPE twice to end.
Installing And Programming The PC Attendant Position
IMI89–195
Installing The PC Attendant Position – 11