![ComAp ID-FLX-Lite-PC Global Manual Download Page 48](http://html1.mh-extra.com/html/comap/id-flx-lite-pc/id-flx-lite-pc_global-manual_2638902048.webp)
InteliDrive Lite - 1.2.1 Global guide
48
1
Operation mode of the engine
2
Indication: “
L
” = Access lock, "
!
” = active Alarm
3
Status of the engine
4
AIN1 - Oil Pressure
5
AIN2 (Engine Temperature) / Soot Level
6
Run Hrs / DEFLevel
7
Engine RPM
5.9.2 InteliDrive Lite Analog inputs screens
First screen:
Operation mode of engine
Oil pressure (AI1 bargraph with protection limits indication)
Water temperature (AI2 bargraph with protection limits indication) or SootLevel indicator
Run Hrs or DEFLevel
Second screen (Analog and binary input/Output values) :
AIN3 (Fuel level, displayed only if is configured)
AIN4 (Pump suction, displayed only if is configured)
AIN5 (Pupm discharge, displayed only if is configured)
AIN6 (Pump flow, displayed only if configured)
Third screen: (Engine values)
5.9.3 IL-NT-AIO Analog inputs screens
AI1 (AI1 bargraph with protection limits indication, displayed only if is configured)
AI2 (AI2 bargraph with protection limits indication, displayed only if is configured)
AI3 (AI3 bargraph with protection limits indication, displayed only if is configured)
AI4 (AI4 bargraph with protection limits indication, displayed only if is configured)
Note:
This screen is shown/hidden depending on whether the IL-NT-AIO is configured or not. Analog output
AO1 is not displayed on any screen!
5.9.4 IL-NT-BIO8 Binary inputs screen
IN: BIO8 BI1 Alarm
IN: BIO8 BI2 Alarm
IN: BIO8 BI3 Alarm
IN: BIO8 BI4 Alarm
IN: BIO8 BI5 Alarm
IN: BIO8 BI6 Alarm
IN: BIO8 BI7 Alarm
IN: BIO8 BI8 Alarm
line is displayed on the following screen