Setpoint group
Engine params 2
Related FW
1.2.1
Range [units]
[-]
Default value
ENABLED
Force value
Step
[-]
Comm object
11086
Related applications
Config level
Standard
Setpoint visibility
Always
Description
The setpoint enables adjustment of the electronic engine control by following settings.
ENABLED: There is a full available control of an electronic engine given by the setting of the ECU unit of the
engine, i.e. Start request, Stop request, Speed request are enabled if available. Default state.
DISABLED: Control of an electronic engine is fully blocked and the InteliDrive Lite can only monitor the
values of an electronic engine.
ECU Control
Setpoint group
Engine params 2
Related FW
1.2.1
Range [units]
MinSpeedLim - MaxSpeedLim [RPM]
Default value
1000 RPM
Force value
Step
1 RPM
Comm object
13095
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Enables to adjust engine speed in ECU via CAN bus. Speed request value after the Idle time is over and no
other speed selection is activated.
Speed request in % range is calculated using the setpoints 0%ofSpeedReq and 100%ofSpeedReq.
ECU SpeedAdj