InteliDrive Lite - 1.2.1 Global guide
44
DOWN
button. Use this button to move down or decrease value
of selected setpoint.
ENTER
button. Use this button to finish editing a setpoint or
moving right in the history page.
RUNNING LED
ALARM LED
5.2 Init screens
5.2.1 Init screen
This is a first screen after controller’s start which is dedicated for information provided by customers such as
contact numbers, service technician contact and customer message for end users of engine. Configuration of
this screen is only done by LiteEdit PC tool.
Note:
Init (welcome) screen appears immediately after power on with ComAp default text. It is possible to
modify it using LiteEdit – Configuration – Init button. There is space for 8 text lines per 21 ASCII characters
each.
5.2.2 Firmware screen
This screen contains information about controller’s type, controller manufacturer ComAp, uploaded firmware,
version of firmware, used application and branch. There is also information about currently configured electronic
engine unit, respectively about ESF file. Details for recognition of configured electronic engine are in chapter
ECU controlled engine support.
Note:
To see firmware information use panel buttons: hold ENTER and press PAGE. This procedure activates
the panel LEDs test as well. The screen disappears itself after app 5 seconds.
5.2.3 Languages screen
InteliDrive IPC controller offers configurable language support. On this screen is possible to switch between
languages configured in controller. Second way, how to change language, is by binary input Lang Selection.
Note:
To switch to Language screen use panel buttons: hold ENTER and press PAGE twice. Press ENTER to
leave this screen.
5.2.4 User interface screen
InteliDrive IPC controller enables to choose the user interface as customer prefers.
There are two choices available: USER or ENGINEER interface
USER
interface is simple menu displaying just measurement, alarm and init screens.
ENGINEER
interface allow changing the controller’s settings, reviewing the history, measurements and
alarms. This mode is default.