Operation – 2
2.2
Operation (HMI/CapTalk
®
)
MESSAGE SCREENS (HMI)
Default Message Screen
When the M-6280A is energized and unattended,
the User Logo lines are displayed.
Re-Close Delay Complete Screen
If the Re-Close Delay is active, the display will cycle
the "Re-Close Delay Complete" Screen that will
indicate in seconds the delay that is complete. When
the Re-Close Delay has timed out, the display will
return to the User Lines.
Resettable Counter Alarm Limit Screen
The Resettable Counter Alarm will initiate a cycling
display as long as the Resettable Counter alarm
is active.
Oscillograph Record Triggered Screen
If the "SCRL OSC Message" feature is enabled
(default setting is enabled) and the Oscillograph
has been triggered, a cycling display indicating
that there is an oscillograph record available for
download will be displayed. The screen will be
displayed until the oscillograph record is cleared or
the "SCRL OSC Message" is disabled. However, if
the Oscillograph file is not cleared, re-enabling this
feature will restart the cycling of the message.
The "Oscillograph Recorded Triggered" cycling
display can be enabled from CapTalk
®
S-6280
Communications Software
by navigating to the
"Oscillograph Cycle Message" (Setup/Oscillograph/
Cycle Message) dialog box (Figure 2-3) and selecting
"Enable". It can also be enabled from the HMI by
navigating to the "Communication HMI" menu.
Figure 2‑3 Oscillograph Cycle Message
Dialog Screen
Setpoint Mismatch Auto Control Mode Screen
If the "Control Open Voltage" setting is less than the
"Control Close Voltage" setting, then the control will
initiate the "Setpoint Mismatch Auto Control Mode"
cycling screen. The message will continue to cycle
as long as this condition exists.
Setpoint Mismatch Remote Control Mode
Screen
If the "Overvoltage Limit" setting is less than the
"Undervoltage Limit" setting, then the control will
initiate the "Setpoint Mismatch Remote Control
Mode" cycling screen. The message will continue
to cycle as long as this condition exists.
Setpoint Mismatch Bank Failed L2
The control will initiate the "Setpoint Mismatch Bank
Failed L2" cycling screen if any of the following
conditions exist:
• "Bank/Switch Failed Level 2" setting is
less than "Bank Status Closed" setting.
• "Bank/Switch Failed Level 2" setting is
less than "Bank Status Open" setting.
This message will continue to cycle as long as any
of these conditions exist.
Setpoint Mismatch Bank Failed L1
The control will initiate the "Setpoint Mismatch Bank
Failed L1" cycling screen if any of the following
conditions exist:
• "Bank/Switch Failed Level 1" setting is
less than "Bank Status Closed" setting.
• "Bank/Switch Failed Level 1" setting is
less than "Bank Status Open" setting.
This message will continue to cycle as long as any
of these conditions exist.
Setpoint Mismatch Control Mode Limits
If the "Maximum Voltage Limit" setting is less than
the "Minimum Voltage Limit" setting, then the control
will initiate the "Setpoint Mismatch Control Mode
limits" cycling screen. The message will continue
to cycle as long as this condition exists.
Maximum Voltage Limit
The maximum voltage limit Alarm will initiate a
cycling display as long as the alarm is active.
Minimum Voltage Limit
The Minimum voltage limit Alarm will initiate a
cycling display as long as the alarm is active.
Remote Overvoltage Limit
The Remote under voltage limit Alarm will initiate a
cycling display as long as the alarm is active.
Summary of Contents for M-6280A
Page 1: ...Instruction Book M 6280A Digital Capacitor Bank Control ...
Page 33: ...This Page Left Intentionally Blank ...
Page 53: ...xx M 6280A Instruction Book This Page Left Intentionally Blank ...
Page 56: ...Introduction 1 1 3 Figure 1 1 Functional Diagram ...
Page 59: ...1 6 M 6280A Instruction Book This Page Left Intentionally Blank ...
Page 66: ...2 7 Operation 2 Figure 2 1 M 6280A Front Panel ...
Page 137: ...3 14 M 6280A Instruction Book Figure 3 13 CapTalk Main Screen Connected Mode ...
Page 172: ...3 49 CapTalk 3 Figure 3 67 CBEMA Settings Dialog Screen ...
Page 179: ...3 56 M 6280A Instruction Book Figure 3 87 M 6280A DNP Configurator Dialog Screen ...
Page 184: ...3 61 CapTalk 3 Figure 3 98 CapPlot Window with Data Logging Data Example ...
Page 185: ...3 62 M 6280A Instruction Book Figure 3 99 CapPlot Window with Oscillograph Data Example ...
Page 191: ...3 68 M 6280A Instruction Book This Page Left Intentionally Blank ...
Page 313: ...M 6280A Instruction Book 4 122 Figure 4 63 Setpoints Dialog Screen VAr Control ...
Page 314: ...Configuration 4 4 123 Figure 4 64 Setpoints Dialog Screen Current Control ...
Page 451: ...D 4 M 6280 Instruction Book This Page Left Intentionally Blank ...