4.4.9.5 Extreme Environment Status
Description
With the help of the Extreme Environment Status, the time is recorded in which the
BVS ID
was exposed to
extreme conditions. In parameter Lifetime Extreme Thresholds, limit values can be configured for the respective
conditions. Parameter Lifetime Extreme Status can be used to read out the status as well as the summed time.
The calculation is based on the features Temperature, Moisture, Vibration.
Mathematics/Algorithm
If one (or more) extreme conditions are met, the
BVS ID
begins to record the time.
Process Data
Object ID
Name
Description
Direction
0x0041 (65)
Lifetime Extreme
One or more extreme conditions present.
Input
0x0042 (66)
Lifetime Extreme Time
Combined total time in which the BVS ID was exposed to an
extreme condition.
Input
ISDU
Name
Index
Subinde
x
Acces
s
Length
Data Type
Data
Storage
Default
Lifetime Extreme
Thresholds
0x00D0
(208)
0
R/W
8 bytes
Yes
Threshold Vibration
1
R/W
4 bytes
FLOAT32
No
100.0
Upper Threshold
Temperature
2
R/W
2 bytes
INT16
No
85
Lower Threshold
Temperature
3
R/W
2 bytes
INT16
No
-25
Lifetime Extreme Status
0x00D1
(209)
0
R
5 bytes
n/a
State
1
R
1 byte
UINT8(ENUM
)
n/a
Time
2
R
4 bytes
UINT32
n/a
Threshold Vibration
Threshold value for the detection of excessive vibrations.
Upper Threshold Temperature
Threshold value for the detection of excessive temperature.
Lower Threshold Temperature
Threshold value for the detection of temperature that is too low.
NOTE
If the power supply is interrupted during this time, the time counter can have an error of maximum 180
seconds.
NOTE
For the internal humidity, it is not possible to parameterize your own limit values.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...