BVS ID-M1280xF1-xx-xxx
88
english
4.3.3.4 Output buffer
Byte address
Bit
7
6
5
4
3
2
1
0
n+0
1st
bit string
-
TI
-
-
-
Reset Error
Trigger
Job
n+1
Status byte
Command identification
n+2
Error byte
Data length byte 0 or data
n+3
Data length byte 1 or data
n+4
Data
n+5
Data
n+6
Data
n+7
Data
n+8
Data
n+9
Data
...
Data
n+31
2nd
bit string
-
TI
-
-
-
Reset Error
Trigger
Job
This output buffer is used by the PLC and read by the
BVS ID
.
Description of the individual signals
Bit String
Bit number
Name
Functional description
0
Job
0: No new job is available.
1: A new job is present.
1
Trigger
Triggers a trigger signal in the BVS ID is triggered. Is acknowledged by the
Waiting For Trigger
bit
is reset.
2
Reset Error
Resets the error bit. After resetting the bit, new buffered errors may be set.
3
Not used
4
Not used
5
Not used
6
TI
A state change during a job indicates that the PLC is ready to receive further data from the BVS ID.
7
Not used
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...