BVS ID-M1280xF1-xx-xxx
156
english
•
•
•
•
•
•
•
•
4.5.3.4 Product Status Signals
Topic
Meaning
Example
balluff/HOSTNAME/
vision/status
Returns the list of status information
entries defined below.
{
"ready": true,
"deviceLocked": false,
"simulationMode": false,
"triggerOverflow": false,
"waitingForTrigger": true,
"inputDataError": false,
"resultDataError": false,
"reportError": false,
"systemError": false,
}
balluff/HOSTNAME/
vision/status/ready
Is set to false, if BVS ID is currently busy,
and cannot process any messages or
signals at this moment.
{"ready": false}
balluff/HOSTNAME/
vision/status/
deviceLocked
This topic is true if
a PLC is connected to the BVS
ID and
the user management is active,
and
no user is logged in as expert or
admin.
{"deviceLocked": false}
balluff/HOSTNAME/
vision/status/
simulationMode
This topic signals that either the File
Device or the Simulation mode in the
Communication Settings of the System
Settings is active.
{"simulationMode": false}
balluff/HOSTNAME/
vision/status/
triggerOverflow
A trigger was discarded since it was still
busy with the analysis of the previous
image.
{"triggerOverflow": false}
balluff/HOSTNAME/
vision/status/
waitingForTrigger
True if BVS ID is waiting for a trigger
signal.
{"waitingForTrigger": true}
balluff/HOSTNAME/
vision/status/
inputDataError
It is set for input buffer (container)
overflow (more input containers
than inspections, so that one
input container was discarded).
It is set for input buffer (container)
underflow (more inspections than
input containers, so that one
input container was used multiple
times).
{"inputDataError": false}
balluff/HOSTNAME/
vision/status/
resultDataError
This topic becomes true as soon as a
result container was not picked up by the
REST client.
{"resultDataError": false}
balluff/HOSTNAME/
vision/status/reportError
This topic becomes true as soon as a
report file could not be transferred and got
lost.
{"reportError": false}
balluff/HOSTNAME/
vision/status/
systemError
This topic becomes true if
A critical temperature of 90 °C
was exceeded inside the device.
The inspection program could not
be imported. instead, the
standard inspection program is
set.
A critical error occurred while
executing the inspection
program.
{"systemError": false}
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...