BVS ID-M1280xF1-xx-xxx
96
english
4.3.5.3 Get Results
After an inspection run, the
BVS ID
via the
Result Data Available
-bit
that result data are ready to be fetched.
With this command a result packet with the size defined in the SensorApp is fetched from the
BVS ID
is
fetched. Depending on the size of the defined data packet, toggling may be necessary, i.e. several data blocks
are transmitted one after the other.
Command:
Sub address
Data
Meaning
n+00
0x02
1st bit string (Job Start)
n+01
0x03
Get Results
n+02
n+03
…
n+31
0x02
2nd bit string
Response:
Sub address
Data
Meaning
n+00
Status byte
n+01
Error byte
n+02
0x02
1st bit string (Job Start)
n+03
CMD status:
0x03
Command was executed successfully, result data is transmitted.
0x15
No result data available.
n+04
User data length byte 0
n+05
User data length byte 1
n+06
Inspection ID byte 0
n+07
Inspection ID byte 1
n+08
Inspection ID byte 2
n+09
Inspection ID byte 3
n+10
Result byte 0
n+11
Result byte 1
n+12
Result byte 2
…
Result byte x
n+31
0x02
2nd bit string
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...