BVS ID-M1280xF1-xx-xxx
62
english
4.1.5.8 Set reference value
Some applications require the code content to be compared with a reference value. The reference value can be
sent using this message. The tool
Inputs
reads this reference value.
Length in bytes
Structure
Value
Description
2
UINT16
34
hex
Message ID
2
UINT16
User data length in bytes, i.e. number of characters of the reference value
UTF-8 encoded reference value
BVS ID
answers with the following response message:
Length in bytes
Structure
Value
Description
2
UINT16
34
hex
Message ID
2
UINT16
02
hex
User data length in bytes
2
UINT16
Result code
Example:
The user wants to send the reference value 'Hello World'. Beforehand, the user has set the reference value
length of 12 bytes in the web interface.
The data encoding must be UTF-8. In this example, the reference value length (11 bytes) to be sent falls below
the user-defined length of the reference value (12 bytes). Thus, the user has to extend sent reference value by
one zero before data transmission such that the byte length of the sent reference value matches the expected
byte length.
Message from the client to
BVS ID
: 34 00 0C 00 48 65 6C 6C 6F 20 57 6F 72 6C 64 00
BVS ID
responds to it with: 34 00 02 00 00 00
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...