![Balluff BVS ID-M1280 F1 Series Configuration Manual Download Page 274](http://html1.mh-extra.com/html/balluff/bvs-id-m1280-f1-series/bvs-id-m1280-f1-series_configuration-manual_3655213274.webp)
BVS ID-M1280xF1-xx-xxx
116
english
System Commands
Command Value
Device Action
0x81 (129)
Application Reset – Sets the threshold value with ISDU index 0xCE Low Signal Quality Threshold to
default 0. The feature is thereby deactivated and the evaluation of index 0xCF subindex 2 always results
in FALSE.
0x82 (130)
Reset Factory Settings – Sets the threshold value with ISDU index 0xCE Low Signal Quality Threshold to
default 0. The feature is thereby deactivated and the evaluation of index 0xCF subindex 2 always results
in FALSE.
Events
Event Code
Event Type
Event – Description – Remedy
Device Status
0x8CFF
(36095)
Warning
Low signal quality level
0 – Device is operating properly.
Variant Dependence
The functionality is available in all variants.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...