BVS ID-M1280xF1-xx-xxx
146
english
4.4.9.14 Variant Configuration
ISDU
Name
Index
Subinde
x
Acces
s
Length
Data Type
Data
Storage
Default
Device Variant
0x0055
(85)
0
R/W
2 bytes
UINT16(ENU
M)
No
1 (Default)
Device Variant
This parameter indicates which variant is currently set. The device variant can be changed either with this
parameter or by using the IO-Link compatibility mode. If this parameter is written, the device variant is not
changed immediately but instead after the
BVS ID
is restarted. If the
device variant is changed via the IO-Link compatibility mode, the change in this parameter is visible immediately.
This parameter is not changed by a reset.
The following device variants are available:
Value
Meaning
Description
0x0001 (1)
Default
Alle 32 bytes of process data are available for the camera
process data interface.
0x0002 (2)
Comprehensive Condition Monitoring
Byte 31 of the input data is reserved for the CCM byte. In this
direction, there are only 31 bytes for the camera data process
interface available.
1.
2.
NOTE
After a variant changeover, an inconsistent configuration may occur because there is no automatic
changeover of parameters.
It is therefore recommended that the setup be done in the following order:
Variant setting
Perform factory reset or set valid parameters.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...