Get device state (health state)
Resource:
diagnostics/health
URL:
http://HOSTNAME/api/balluff/v1/diagnostics/health
The device health indicates the status of the
BVS ID
as defined by NAMUR Recommendation NE107. Clients
can read this variable to determine the device condition.
Response:
Object
Content
health
Device Status. Possible values are:
NORMAL_0
FAILURE_1
CHECK_FUNCTION_2
OFF_SPEC_3
MAINTENANCE_REQUIRED_4
Device
Status
Description
NORMAL_0
Device is operating properly
FAILURE_1
Process data invalid due to malfunction in the device
or its peripherals. The device is unable to perform its
intended function.
CHECK_FUN
CTION_2
Process data are temporarily invalid due to intended
manipulations on the device.
OFF_SPEC_
3
Although the process data are valid, internal
diagnostics indicate that the device is operating
outside its specified measuring range or
environmental conditions.
MAINTENAN
CE_REQUIR
ED_4
Although the process data are valid, internal
diagnostics indicate that the device is close to lose
its ability of correct functioning.
Example:
{
"health"
: {
"value"
:
"NORMAL_0"
}
}
NOTE
For the determination of the device status, only data from the IO-Link controller are evaluated. The
states of the SensorApp are not included in this calculation. For example, the device state does not
change to CHECK_FUNCTION_2, when changing into the Configuration mode in the web interface.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...