BVS ID-M1280xF1-xx-xxx
english
93
4.3.5 Commands
The
BVS ID
can be controlled via commands in the "Ready" status (Ready - signal "1").
In this state, the PLC can send commands to the
BVS ID
and then receives a response containing an
acknowledgement of the command (CMD status) and the corresponding data.
Command
Code
Functional description
Set Inspection ID
0x01
Sets the current inspection program based on the passed ID.
Get Inspection ID
0x02
Queries the current inspection ID.
Get Results
0x03
Fetches the result container.
Set Inputs
0x04
Sends the reference values to the BVS ID.
Get Date Time
0x06
Fetches the time stamp.
Set Date Time
0x07
Sets the system time in the BVS ID.