![Balluff BVS ID-M1280 F1 Series Configuration Manual Download Page 249](http://html1.mh-extra.com/html/balluff/bvs-id-m1280-f1-series/bvs-id-m1280-f1-series_configuration-manual_3655213249.webp)
BVS ID-M1280xF1-xx-xxx
english
91
•
•
•
•
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
4.3.4.1 Toggle mechanism
If more data is to be transferred with a command or with a response than is available in the input / output buffer,
a toggle mechanism is used. This means that further data is transferred sequentially in further PLC cycles.
This only concerns the commands
Query results
(0x03) and
Set reference values
(0x04)
For signaling purposes, the following are used during transmission
PLC
→
BVS
BVS ID
- the
TI
-bit (Toggle-In) in the output buffer
BVS ID
→
PLC - the
TO
-bit (Toggle-Out) in the input buffer is
used.
Before and after the end of a communication cycle between PLC and
BVS ID
the
TI
-bit must be 0. The
BVS ID
automatically also always sets the
TO
-signal to 0 after a communication.
PLC writes in the output buffer: command identifier, data length and the first part of the data. (The data
length is the length of the total data to be transmitted).
PLC deletes
TI
(if still set).
PLC sets
.
BVS ID
reads command ID, data length and (partial) data and recognizes from the data length and size
of the cyclic buffer that further exchange cycles are necessary.
BVS ID
sets
Job Start
and
TO
.
PLC recognizes the change of state of the
TO
and writes the next partial data into the output buffer.
PLC inverts
TI
.
BVS ID
recognizes the inverted
TI
and reads the next partial data.
BVS ID
inverted
TO
.
If further partial data are to be transferred, proceed with 6. When all data have been transferred, proceed
with 11.
BVS ID
set
Job End
.
PLC reads command status, data length and (partial) data.
PLC deletes
Job
.
PLC deletes
TI
.
BVS ID
deletes
Job End
,
Job Start
and
TO
.
NOTE
If toggling is not required, the toggle bits TI (PLC) and TO (
BVS ID
) remain at 0 and are not considered!
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...