BVS ID-M1280xF1-xx-xxx
58
english
•
•
BVS ID
answers with:
16 00 02 00 00 00 (Reset errors response message)
12 00 02 00 20 00 (Status message)
Das 0th bit of the high byte, which indicated
Trigger Error
is being reset to binary "0". The 4th bit of the low byte,
which indicates
Ready
is unaffected by the reset.
4.1.5.4 Get inspection ID
Gets the program number of the active inspection.
Length in bytes
Structure
Value
Description
2
UINT16
30
hex
Message ID
2
UINT16
00
hex
User data length in bytes
BVS ID
answers with a response message containing the Inspection ID.
Length in bytes
Structure
Value
Description
2
UINT16
30
hex
Message ID
2
UINT16
04
hex
User data length in bytes
2
UNIT16
Result code (02
hex
for OK Inspection ID or 16
hex
for NOK Busy)
2
UINT16
if OK Inspection ID: the set Inspection ID
if NOK Busy: the constant value of 0
Example:
Message from the client to
BVS ID
: 30 00 00 00
BVS ID
responds to it with: 30 00 04 00 02 00 15 00
The last 2 bytes representing the Inspection ID (15 00) is interpreted as 21 in decimal system.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...