4.4.9.2 Operating Hours Counter
Description
The operating hours counter can record the operating hours of a device accurately to the second. There is a
total of three operating hours counters. In addition to an operating hours counter for the operating hours since
the
start of the device, there is a total operating hours counter and a customer-specific operating hours counter that
can be reset. The storage interval is configurable and the operating hours are not stored once 1,000,000
storage cycles have been reached.
The output of the operating hours can serve as a time control for the service interval as well as for preventative
maintenance. Schedules for regular service can be tied to the operating hour values. Moreover, a high value of
the total operating hours is indicative of intensive use of the
BVS ID
and possible deterioration of the
performance. The risk of failure can be countered preventatively through replacement.
Algorithm
While the counter is incremented every second, the storage interval doubles after each save operation. Starting
with a save operation after 1 minute, then after 2 minutes, then after 4 minutes, then after 8 minutes, up to a
maximum storage rate of 12 minutes.
Process Data
Object ID
Name
Description
Direction
0x001B (27)
Current Operating Hours
Output of the current operating hours counter
Input
0x001C (28)
Total Operating Hours
Output of the total operating hours counter
Input
0x001D (29)
Custom Operating Hours
Output of a user-defined operating hours counter
Input
ISDU
Name
Index
Subinde
x
Acces
s
Length
Data Type
Data
Storage
Default
Operating Hours
Counter
0x0057
(87)
0
R
12
bytes
n/a
Current Operating
Hours
1
R
4 bytes
UINT32
n/a
-
Total Operating Hours
2
R
4 bytes
UINT32
n/a
-
Custom Operating
Hours
3
R
4 bytes
UINT32
n/a
-
Operating Hours Saving
Mode
0x0074
(116)
0
R/W
1 byte
UINT8(ENUM
)
Yes
0
Current Operating Hours
This parameter saves the value of the operating hours since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours since the first commissioning in seconds.
NOTE
The maximum counter value that can be saved is 1,000,000 and, with a switch-on and switch-off every
12 minutes (with static counter), this means a service life of over 20 years. If switched on and off more
frequently or in the case of dynamic storage, the maximum storage time is reduced depending on the
application.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...