4.4.8.3 Network Settings
Description
With the network setting the IP configuration can be set and read.
ISDU
Name
Index
Subinde
x
Acces
s
Length
Data Type
Data
Storage
Default
Network Settings
0x00B
E
(190)
0
R/W
46
bytes
No
IP Address
1
R/W
≤ 15
bytes
STRING
No
Subnet Mask
2
R/W
≤ 15
bytes
STRING
No
Gateway Address
3
R/W
≤ 15
bytes
STRING
No
DHCP
4
R/W
1 Bit
BOOL
No
IP Address
Here the fixed IP address of the
BVS ID
can be set and read (see SensorApp network settings).
The IP address must correspond to the format "x.x.x.x". An IP address obtained dynamically via DHCP is not
displayed here.
Subnet mask
Here the subnet mask of the fixed IP configuration of the
BVS ID
can be set and read (see SensorApp network
settings).
Gateway address
Here the gateway address of the fixed IP configuration of the
BVS ID
can be set and read. (see SensorApp
network settings).
DHCP
Here the DHCP option of the
BVS ID
can be set and read. (see SensorApp network settings).
4.4.8.4 Process Data
Description
A protocol is transferred in the process data. The functional principle and the available commands are described
in the chapter "
IO-Link / Fieldbus Process Data Protocol
".
NOTE
Inconsitent or invalid network settings are rejected by the
BVS ID
without error notification. It is thus
advisable to read the network settings after having them set and to compare the actual settings to the
intended settings.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...