Alarm Teaching Status
Bit
Description
0
Device has not yet been taught-in, no reference orientation set, inclination value not available.
1
Device has been taught-in, reference orientation is set, inclination value is available.
Use system command 0xC0 for teaching-in and defining reference orientation.
Alarm Inclination Status
Bit
Description
0
Device is in its taught-in position/orientation.
1
Device is incorrectly oriented; inclination is equal to or greater than the threshold value.
Reference Taught Position
X-, Y-, Z-coordinate values of the reference position set (taught-in) by system command 0x0C.
Values: −16…+16, without vibrations, they should be in the range −1…+1
Unit: g (9.81 m/s2)
Default: –
Inclination Deviation Value
Angle between the taught-in reference orientation and the actual orientation:
Values: 0…180
Unit: Degrees (°)
System Commands
System Commands for teaching-in and defining the reference orientation.
Command Vlaue
Device Action
0xC0 (192)
Set Reference Orientation – Sets the reference orientation of the
actual position of the BVS ID.
Responses: ACK: command successful, reference stored.
0x81 (129)
Application Reset – Resets the inclination alarm configuration to the
default value of the firmware.
0x82 (130)
Reset Factory Settings – Resets the inclination alarm configuration to the default value of the firmware.
Events
Event
Code
Event Type
Event – Description – Remedy
Device Status
0x8CD0
(36048)
Warning
Inclination alarm
→
Check installation.
1 – Maintenance-Required
This event shows that the
BVS ID
has lost its original position (taking the threshold value into account). The
mounting of the
BVS ID
should be checked.
The
BVS ID
is still functional, but the measured values could be invalid since the sensor.
NOTE
The device cannot calculate the inclination until the reference position has been taught-in.
NOTE
The device cannot calculate the inclination until the reference position has been taught-in
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...