![Balluff BVS ID-M1280 F1 Series Configuration Manual Download Page 278](http://html1.mh-extra.com/html/balluff/bvs-id-m1280-f1-series/bvs-id-m1280-f1-series_configuration-manual_3655213278.webp)
BVS ID-M1280xF1-xx-xxx
120
english
Statistics Data Configuration: Time Period Unit
The time unit Time Period Unit can be set with one of the below values to calculate the minimum, maximum and
average. For example, to calculate minimum, maximum and average for all 1-hour values, hours can be selected
as the unit for this subindex.
Value
Meaning
Description
0x01 (1)
Seconds
Seconds
0x02 (2)
Minutes
Minutes
0x03 (3)
Hours
Hours
0x04 (4)
Days
Days
0x05 (5)
Samples
Measurement
values
Statistics Data Configuration: Time Period Value
Time Period Value can be set from 1 second to 1 week or 1 to 1000 measurement values. Over what average
minimum, maximum and average is the calculation to be performed. Other checks are performed internally and,
if an unsuitable selection is made for Time Period Value, a standard error is returned.
Time Period Unit
Time Period Value (value range)
Seconds
1…1000
Minutes
1…100
Hours
1…24
Days
1…7
Measurement
values
1…1000
Statistics Data Configuration: Moving Average Window Unit
For the moving average, one of the units from the table below should be selected. For example, to calculate the
moving average for groups of 100 measurement values, measurement values (samples) can be selected as the
unit.
Value
Meaning
Description
0x01 (1)
Seconds
Seconds
0x02 (2)
Minutes
Minutes
0x03 (3)
Hours
Hours
0x04 (4)
Samples
Measurement
values
Statistics Data Configuration: Moving Average Window Value
The value for the moving average (moving average window) must be in the value range. To calculate the moving
average, it is possible to select, for example, 1…1000 measurement values.
Moving Average Window Unit
Moving Average Window Value (value range)
Seconds
1…1000
Minutes
1…100
Hours
1…24
Measurement
values
1…1000
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...