BVS ID-M1280xF1-xx-xxx
34
english
Parameters
Description
Data type
Sorting criterion
Determines the criteria by which found codes will be sorted.
Sort mode
Description
Position x (left
→
right)
Codes are sorted by the x coordinate of their
midpoint from left to right.
Position x (right
→
left)
Codes are sorted by the x coordinate of their
midpoint from right to left.
Position y (top
→
bottom)
Codes are sorted by the y coordinate of
their midpoint from top to bottom.
Position y (bottom
→
top)
Codes are sorted by the y coordinate of their
midpoint from bottom to top.
Enum
Code quality
Activates/deactivates code quality assessment and is used to specify the norm that is used
as the basis for this quality assessment. If
Assess quality
is active,
Read timeout
can't be
used.
Enum
Tool timeout [ms]
Duration of manually selected timeout for code search in milliseconds. It is possible that the
search ends before the selected timeout, in case the search includes multiple 2D code
types or 1D and 2D code types.
Int
NOTE
Sorting takes place after the code search. This means that the results are not
dependent on the sort mode. Only the order of results will change with the
sorting mode.
NOTE
Assessing the code quality will increase the execution duration of this tool
significantly.
NOTE
In order to successfully assess code quality, a certain area around the code is
required. If quality assessment should fail even if the code is found, ensure that
the code is not too close to the image or aoi border.
NOTE
For the "Pharmacode" and "2/5 Industrial" code types, not all nine quality
characteristics are defined according to the ISO/IEC 15416 standard. The
minimum code quality is also not defined according to the standard.
NOTE
If enabled, the obtained quality is transformed into a condition monitoring signal
quality value. More information about the transformation mechanism is provided
in section
Overview of IO-Link Data and Functions / Primary Device Functions /
Signal Quality / Mathematics/Algorithm.
NOTE
This is not an absolute timeout but instead only a reference value for the tool,
where additional times are added. Therefore it is not to be treated equal with the
machine cycle.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...