![Balluff BVS ID-M1280 F1 Series Configuration Manual Download Page 211](http://html1.mh-extra.com/html/balluff/bvs-id-m1280-f1-series/bvs-id-m1280-f1-series_configuration-manual_3655213211.webp)
BVS ID-M1280xF1-xx-xxx
english
53
•
•
•
•
•
•
•
•
•
•
•
•
Value
(dec)
Value
(hex)
Bit
Name
Description
Reset to binary "0"
32
20 00
5
Ready
This bit signals that BVS ID is currently
ready. It is reset while BVS ID performs an
administrative task that prevents it from
processing commands. The bit is
particularly reset
during the startup of BVS ID
including the load of the inspection,
during the change of an inspection
program by means of the web
interface or the TCP/UDP
communication interface,
while the user resides in the
configuration mode,
during Auto Setup,
if the File Device is selected as
Image source in the Inputs tab of
the configuration mode page, or
the System error is set.
BVS ID is not considered to be busy during
the execution of an inspection, and the
Ready
bit will be set. For sequence control
during an inspection run, the bit
Waiting For
Trigger
is provided.
Automatically, as soon as the BVS ID performs
an administrative task.
128
80 00
7
Device
Locked
This bit signals that a PLC has exclusive
control over the BVS ID. The bit is set when
a PLC connects via a communication
interface to the BVS ID. The bit is
particularly reset
when the PLC disconnects from
the BVS ID,
a user logs in as
expert
or
admin
on the client, or
the user management gets
deactivated.
By receiving a status message or through
the status display on the web interface
other participants can recognize if a PLC
has exclusive control.
Automatically, as soon as a PLC disconnects
from the BVS ID, a user logs in as
expert
or
admin
on the client, or the user management
gets deactivated.
256
00 01
8
Trigger
Overflow
This bit signals that a trigger has been
received while BVS ID was not waiting for a
trigger, i.e. while the bit
Waiting For Trigger
was binary "0". The behavior upon such an
unexpected trigger is undefined: the trigger
might cause an image acquisition, or it
might not.
By the user with the command
Reset errors
(0x16) and automatically during change to
configuration mode.
1024
00 04
10
Report Error
This bit becomes active as soon as a report
file could not be transferred and got lost.
By the user with the command
Reset errors
(0x16) and automatically during change to
configuration mode.
4096
00 10
12
Input Data
Error
It is set for input container overflow (more
input containers than inspection results, so
that one input container was discarded or if
received reference value is too large at the
time of execution of tool Inputs) or
underflow (more inspection results than
input containers, so that one input container
was used multiple times or if the received
reference value is too small at the time of
execution of tool Inputs).
By the user with the command
Reset errors
(0x16) and automatically during change to
configuration mode.
32768
00 80
15
System
Error
This bit becomes active if
A critical temperature of 90 °C was
exceeded inside the device.
The inspection program could not
be imported. instead, the standard
inspection program is set.
A critical error occurred while
executing the inspection program.
Automatically, as soon as the system error is
resolved.
Example 1:
Status message from
BVS ID
to the client
: 12 00 02 00 21 00
The status word 21 00 can be interpreted as: 0b 0010 0001 0000 0000. The 0th and the 5th bit are binary "1".
Therefore, the status message indicates
Ready
and
Waiting For Trigger
.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...