![Balluff BVS ID-M1280 F1 Series Configuration Manual Download Page 288](http://html1.mh-extra.com/html/balluff/bvs-id-m1280-f1-series/bvs-id-m1280-f1-series_configuration-manual_3655213288.webp)
BVS ID-M1280xF1-xx-xxx
130
english
4.4.9.6 Internal Temperature
Description
The
BVS ID
has internal temperature monitoring. This records the device temperature as well as the maximum
and minimum values since production and since the last time the
BVS ID
was restarted.
An upper and a lower threshold value can be defined for the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or undercut, the
BVS ID
triggers IO-Link events.
Process Data
Object ID
Name
Description
Direction
0x004E (78)
Temperature Status Customer
Limits
Temperature status – Warning related to the configured
customer limits [Index 0x0053].
Set when out of limits.
Input
0x004F (79)
Temperature Status Device
Limits
Temperature status – Warning related to the device limits.
Set when out of limits.
Input
0x0050 (80)
Device Temperature
Current device temperature in °C.
Input
ISDU
Name
Index
Subinde
x
Acces
s
Length
Data Type
Data
Storage
Default
Device Temperature
0x0052
(82)
0
R
10
bytes
n/a
Device Temperature
1
R
2 bytes
INT16
n/a
Minimum Device
Temperature Since
Reset
2
R
2 bytes
INT16
n/a
Maximum Device
Temperature Since
Reset
3
R
2 bytes
INT16
n/a
Lifetime Minimum
Device Temperature
4
R
2 bytes
INT16
n/a
Lifetime Maximum
Device Temperature
5
R
2 bytes
INT16
n/a
Device Temperature
Alarm Configuration
0x0053
(83)
0
R/W
4 bytes
INT16
Yes
Lower Alarm Level
Device Temperature
1
R/W
2 bytes
INT16
No
-25
Upper Alarm Level
Device Temperature
2
R/W
2 bytes
INT16
No
85
Device Temperature
Device Temperature contains information about the device temperature (current value in °C), the minimum or
maximum device temperature since the last time the device was switched on/reset (in °C) and minimum or
maximum device temperature during the lifetime of the
BVS ID
(in °C).
NOTE
The internal device temperature is measured in the
BVS ID
and is therefore higher than the ambient
temperature. The level of this increased temperature depends on the ambient temperature, the
ventilation of the
BVS ID
and the device settings.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...