4.4.9.16 Process Data Info and Configuration
Description
Process data information and configuration offers various possibilities related to process data:
Selection of a process dataset specified by the
BVS ID
Information about the structure of the input and output data
Information about the last valid value for input and output data
As a diagnosis function, monitoring of the updates of certain process values is available. If these are not
updated in the specified time, the
BVS ID
sends corresponding diagnosis messages.
Invalid Process Data
Input data (from the device to the master) is only marked as invalid if the
BVS ID
has the Failure device status.
Invalid output data (from the master to the device) is not processed by the
BVS ID
. The
BVS ID
then operates
only with the next valid data. Running commands will be possibly aborted.
ISDU
Name
Index
Subinde
x
Acces
s
Lenght
Data Type
Data
Storage
Default
Process Data Input
Descriptor
0x000E
(14)
0
R
96
bytes
UINT8[ ]
n/a
Process Data Output
Descriptor
0x000F
(15)
0
R
96
bytes
UINT8[ ]
n/a
-
PD Description
This parameter is used to specify the structure of the currently selected process data profile for input and output
data. The individual process data variables are described.
The total list is possible via subindex 0, a single entry is possible using a specific subindex. Subindex 1
corresponds to the least significant (or the element most recently transferred in the process data stream). When
reading out the entire list, this element is transferred first.
The length of the list is dependent on which process data profile is selected. A single element has a length of 3
bytes.
Byte number
Contents
Values
Byte 1
Data type
0: OctetStringT
1: Set of BoolT
2: UIntegerT
4: Float32T
5…255: reserved
Byte 2
TypeLength
0…255 bits
Byte 3
Bit offset
0…255 bits
NOTE
In the case of individual pieces of faulty data, the data is not marked as invalid but is instead replaced
by substitution values or error codes. This is to be considered during the evaluation.
Summary of Contents for BVS ID-M1280 F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 41: ...BVS ID M1280xF1 xx xxx deutsch 39...
Page 96: ...BVS ID M1280xF1 xx xxx 94 deutsch Ablaufdiagramm Handshake mit Input Toggle...
Page 157: ...956115_AB DE E23 nderungen vorbehalten Ersetzt K22...
Page 158: ......
Page 159: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 160: ...www balluff com...
Page 197: ...BVS ID M1280xF1 xx xxx english 39...
Page 250: ...BVS ID M1280xF1 xx xxx 92 english Flowchart Handshake with Input Toggle...
Page 315: ...956115_AB EN E23 Subject to modification Replaces K22...