![ABB FSO-21 User Manual Download Page 422](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728422.webp)
422 Parameters
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
SS1.22 SS1 completed
output
Sets the digital output that indicates the
completion of the SS1 function. See the
diagrams in section
on
page
.
None
No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7
Single output X113:7
DO X113:8
Single output X113:8
DO X113:9
Single output X113:9
DO X114:7
Single output X114:7
DO X114:8
Single output X114:8
DO X114:9
Single output X114:9
41
SLSx
Parameters for the SLS1…4 functions
SLSx.02 SLS
acknowledgement
Sets the acknowledgement method used in
the SLS1
…
4 functions.
Manual
The FSO module reads the external SLS
acknowledgement signal through the digital
input defined by parameter
. The FSO
module accepts the acknowledgement after
the SLS request has been removed and the
SLS limit has been achieved (that is, SLS
monitoring is on).
Automatic
The FSO module generates the SLS
acknowledgement signal automatically after
the SLS request has been removed and the
SLS limit has been achieved (that is, SLS
monitoring is on).
Index
Name/Value
Description
Factory
default
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...