![ABB FSO-21 User Manual Download Page 203](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728203.webp)
PROFIsafe 203
Unsig
ned16
(used
as
bits)
2
0
Variable_SLS_req
uest
Variable SLS (Safely-limited speed) activation
requested by the controller and the Variable SLS
limit is valid.
1
Reserved
*)
Must not be used (must be 0).
2
SF_end_ack
Safety function ending acknowledgement = 1,
no acknowledgement = 0.
3
Reserved
*)
Must not be used (must be 0).
4
SSM4_activate
SSM4 (Safe speed monitor) activation requested by
the controller.
5
SSM3_activate
SSM3 (Safe speed monitor) activation requested by
the controller.
6
SSM2_activate
SSM2 (Safe speed monitor) activation requested by
the controller.
7
SSM1_activate
SSM1 (Safe speed monitor) activation requested by
the controller.
Unsig
ned16
(used
as
bits)
3
0
Safe_output_X114
_9_ctrl
State of the safe output X114:9 (see section
on page
). 1 = 24 V, 0 = 0 V.
1
Safe_output_X114
_8_ctrl
State of the safe output X114:8 (see section
on page
). 1 = 24 V, 0 = 0 V.
2
Safe_output_X114
_7_ctrl
State of the safe output X114:7 (see section
on page
). 1 = 24 V, 0 = 0 V.
3
Safe_output_X113
_9_ctrl
State of the safe output X113:9 (see section
on page
). 1 = 24 V, 0 = 0 V.
4
Safe_output_X113
_8_ctrl
State of the safe output X113:8 (see section
on page
). 1 = 24 V, 0 = 0 V.
5
Safe_output_x113
_7_ctrl
State of the safe output X113:7 (see section
on page
). 1 = 24 V, 0 = 0 V.
6
Negative_Scaling
Selects whether Variable SLS limit is scaled for
negative direction. 0 = Limit scaled, 1 = Limit not
scaled (100%).
7
Positive_Scaling
Selects whether Variable SLS limit is scaled for
positive direction. 0 = Limit scaled, 1 = Limit not
scaled (100%).
Intege
r16
4
Variable_SLS_limit
_MSB
Safely-limited speed relative limit (MSB) [0.01%]
Intege
r16
5
Variable_SLS_limit
_LSB
Safely-limited speed relative limit (LSB) [0.01%]
*)
If the PROFIsafe message includes a safety function request which is not supported or if the
safety function has not been configured, the FSO module activates the SSE function and
generates an FSO configuration fault (see chapter
Type
Octet Bit Name
Description
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...