![ABB FSO-21 User Manual Download Page 202](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728202.webp)
202 PROFIsafe
ABB_PS1 profile F-Output user data
This table shows the bit order of the F-Output data, which is included in the
PROFIsafe message sent to the FSO module from the safety PLC. For all the bits in
the F-Output data, one (1) means active and zero (0) non-active.
Type
Octet Bit Name
Description
Unsig
ned16
(used
as
bits)
0
0
SLS2_request
SLS2 (Safely-limited speed) activation requested by
the controller.
1
SLS1_request
SLS1 (Safely-limited speed) activation requested by
the controller.
2
Reserved
*)
Must not be used (must be 0).
3
Reserved
*)
Must not be used (must be 0).
4
SS1_request
SS1 (Safe stop 1) activation requested by the
controller.
5
SSE_request
SSE (Safe stop emergency) activation requested by
the controller.
6
POUS_request
POUS (Prevention of unexpected start-up)
activation request by the controller.
7
STO_request
STO (Safe torque off) activation requested by the
controller.
Unsig
ned16
(used
as
bits)
1
0
SDI_N_ activate
SDI_N (Safe direction) activation requested by the
controller.
1
SDI_P_ activate
SDI_P (Safe direction) activation requested by the
controller.
2
Reserved
*)
Must not be used (must be 0).
3
Reserved
*)
Must not be used (must be 0).
4
Reserved
*)
Must not be used (must be 0).
5
Reserved
*)
Must not be used (must be 0).
6
SLS4_request
SLS4 (Safely-limited speed) activation requested by
the controller.
7
SLS3_request
SLS3 (Safely-limited speed) activation requested by
the controller.
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...