24 Introduction to the manual
FbEq16
16-bit fieldbus equivalent: The scaling between the value shown on the
panel and the integer used in communication when a 16-bit value is
selected for transmission to an external system.
FbEq32
32-bit fieldbus equivalent: The scaling between the value shown on the
panel and the integer used in communication when a 32-bit value is
selected for transmission to an external system.
F-Device
Device that is able to communicate using PROFIsafe, eg, the FSO
module.
F-Host
Programmable logic controller (PLC) that is able to communicate using
PROFIsafe.
F-Input
PROFIsafe frame user data from that is sent from the F-Device (FSO) to
the F-Host (PLC).
F-Output
PROFIsafe frame user data from that is sent from the F-Host (PLC) to
the F-Device (FSO).
F-Parameters
Set of PROFIsafe parameters that all PROFIsafe devices support.
F-Parameters are sent from the F-Host (PLC) to the F-Device (FSO)
when the PROFIsafe connection is created.
FBA
Fieldbus adapter parameter (drive parameter group 50)
FB module
Fieldbus adapter module (FPNO-21 or FENA-21)
FENA-21
Optional Ethernet adapter module for EtherNet/IP
™
, Modbus TCP and
PROFINET IO protocols
FIT
Failure in time: 1E-9 hours. Expected failure rate of semiconductors and
other electronic devices. (IEC 61508)
FPNO-21
PROFINET fieldbus adapter module
FSE-31
Pulse encoder interface module which can be used in safety
applications
FSO-12
Safety functions module which does not support the use of encoders
FSO-21
Safety functions module which supports the FSE-31 module and the
use of safety encoders
Functional safety
Functional safety is part of the overall safety that depends on a system
or equipment operating correctly in response to its inputs.
Generator mode
Drive is taking energy from the controlled application
GND
Ground
GSD file
General Station Description file that describes the basic capabilities of a
device in a specified form. PROFINET uses GSDML files which are
GSD files written in XML format.
HAT
Host acknowledgement time
Hazard
Potential source of harm (physical injury, or damage to health or
equipment)
HFT
Hardware fault tolerance (IEC 61508)
Term /
Abbreviation
Description
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...