82 Safety functions
With an encoder
A
SS1-t delay for STO (parameter
): Time after which the FSO activates the STO
function regardless of the motor speed.
B
Zero speed with encoder (parameter
): Speed limit for activating the drive
STO function. The safety function is completed and the SS1 completed indication
(parameter
) goes on. The acknowledgment becomes allowed.
C
Response time (depends on system configuration, see page
)
Drive STO state
& indication
SS1 request
Motor speed
Time
SS1 state &
indication
1
2
5
3
A
B
C
3b
SS1 completed
indication
SS1.14
4
- ->
Safe torque off (STO)