![ABB FSO-21 User Manual Download Page 28](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728028.webp)
28 Introduction to the manual
STO
Safe torque off (EN/IEC 61800-5-2). In this manual, this term is used in
two different contexts:
•
the STO circuit in the drive (the drive STO function)
•
the
STO safety function in the FSO module.
Safety functions in the FSO module (eg, STO, SSE, SS1 and POUS)
activate the drive STO function, that is, open the drive STO circuit. In
addition, some safety functions can activate the STO safety function in
the FSO module, which in turn opens the drive STO circuit. See section
Dependencies between safety functions
on page
.
Stop category
There are three categories of stop functions:
• stop category 0: an uncontrolled stop where power to the machine
actuators is removed immediately
• stop category 1: a controlled stop where the machine actuators have
power for stopping, after which the power is removed
• stop category 2: a controlled stop where the machine actuators
continue to have power.
Stop category 0 and 1 definitions also apply to Emergency stop
categories.
T1
Proof test interval (IEC 61508). T1 is a parameter used to define the
probabilistic failure rate (PFH or PFD
avg
) for the safety function or
subsystem. Performing a proof test at a maximum interval of T1 is
required to keep the SIL capability valid. The same interval must be
followed to keep the PL capability (EN ISO 13849) valid. See also
section
on page
.
T
m
See Mission time.
TP
Test pulse. Term diagnostic pulse is used in this manual.
TWCDT
Total worst-case delay time
Validation
Confirmation by, for example, analysis that the safety system meets the
functional safety requirements of the specific application.
Verification
Confirmation by, for example, testing that the safety system meets the
requirements set by the specification.
WCDT
Worst-case delay time
WD
Watchdog
ZCU-
xx
Drive control unit type (xx = version number)
Zero speed
Speed limit where a ramp stop safety function is considered to be
completed and drive STO is activated. The acknowledgement of the
safety function becomes possible when this speed is reached.
Zero speed limit is given with parameter
on page
or, when an encoder is used,
on page
λ
d
Dangerous failure rate
λ
du
Dangerous failure rate, undetected failures
Term /
Abbreviation
Description
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...