PROFIsafe 209
ABB_PS2 profile F-Input user data
This table shows the bit order of the F-Input user data, which is included in the
PROFIsafe message sent from the FSO module to the safety PLC. For all the bits in
the F-Input data, one (1) means active and zero (0) non-active.
Note
: In the Fail-safe and Configuration states, all the bits in the PROFIsafe message
are set to “0”. In these cases, you can read the FSO state from:
• Siemens PLC: bits QBAD and PASS_OUT in the PROFIsafe data block
• ABB PLC: bit Device_Fault in the PROFIsafe data structure.
See also section
on page
Type
Octet Bit Name
Description
Unsig
ned16
(used
as
bits)
0
0
SLS2_active
SLS2 (Safely-limited speed) is active. Active when
the SLS2 function is active and the motor speed is
below the SLS2 limit (that is, when the SLS2
monitoring is on).
1
SLS1_active
SLS1 (Safely-limited speed) is active. Active when
the SLS1 function is active and the motor speed is
below the SLS1 limit (that is, when the SLS1
monitoring is on).
2
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
Reserved
*)
The value is 0. Must be ignored by the F-Host.
4
SS1_active
SS1 (Safe stop 1) function is active.
5
SSE_active
SSE (Safe stop emergency) function is active.
6
SBC_active
SBC (Safe brake control) function is active.
7
STO_active
STO (Safe torque off) function is active.
Unsig
ned16
(used
as
bits)
1
0
Reserved
*)
The value is 0. Must be ignored by the F-Host.
1
Reserved
*)
The value is 0. Must be ignored by the F-Host.
2
Reserved
*)
The value is 0. Must be ignored by the F-Host.
3
Reserved
*)
The value is 0. Must be ignored by the F-Host.
4
SAR1_active
SAR1 (Safe acceleration range) is active.
5
SAR0_active
SAR0 (Safe acceleration range) is active.
6
SLS4_active
SLS4 (Safely-limited speed) is active. Active when
the SLS4 function is active and the motor speed is
below the SLS4 limit (that is, when the SLS4
monitoring is on).
7
SLS3_active
SLS3 (Safely-limited speed) is active. Active when
the SLS3 function is active and the motor speed is
below the SLS3 limit (that is, when the SLS3
monitoring is on).
Summary of Contents for FSO-21
Page 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 34: ...34 Safety information and considerations ...
Page 52: ...52 Overview ...
Page 236: ...236 PROFIsafe ...
Page 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Page 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Page 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Page 286: ...286 PROFIsafe ...
Page 304: ...304 Installation ...
Page 400: ...400 Configuration ...
Page 488: ...488 Verification and validation ...
Page 506: ...506 Fault tracing ...
Page 514: ...514 Maintenance ...
Page 536: ...536 Technical data ...