Drive set-up procedure
14.3.9 Absolute value detection
14-78
14.3.9 Absolute value detection
For machine data setting for the absolute value encoder, see Section 14.1.5 Motor Encoder
and Section 14.1.6 Separately Mounted Encoder.
Other primary CNC data required for absolute value detection function are listed below.
• MD34090 ENC_MOVE_DIST_CORR [0] (For each axis)
Meaning:
Origin position offset (motor encoder)
Setting value: [mm] or [deg]
Note: When absolute value detection function is enabled, the origin setting
value is written into this parameter.
• MD34090 ENC_MOVE_DIST_CORR [1] (For each axis)
Meaning:
Origin position offset (separately mounted encoder)
Setting value:
[mm] or [deg]
Note: When absolute value detection function is enabled, the origin setting
value is written into this parameter.
• MD34100 REFP_SET_POS [0] (For each axis)
Meaning:
After return to reference point, coordinate system offset
(motor encoder)
Setting value: [mm] or [deg]
• MD34100 REFP_SET_POS [1] (For each axis)
Meaning:
After return to reference point, coordinate system offset
(separately mounted encoder)
Setting value: [mm] or [deg]
• MD34200 ENC_REFP_MODE [0] (For each axis)
Meaning:
Return to reference point mode setting (motor encoder)
Setting value: 0---No origin pulse
1---C phase return to reference point
Note: When the absolute value detection function is enabled, you must
specify "0".
• MD34200 ENC_REFP_MODE [1] (For each axis)
Meaning:
Return to reference point mode setting (separately mounted encoder)
Setting value: 0---No origin pulse
1---C phase return to reference point
Note: When the absolute value detection function is enabled, you must
specify "0".
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...