11.1 Drive Parameter Screen Operation
11-7
11.1.4 Conditions for the modified parameters to be effective
For the details about the conditions on which the modified parameters are enabled, see the
⑦
Conditions to be Effective described on the section 11.1.2 Screen configuration. Below is
shown the meanings of each symbol.
11.1.5 Protection level
Operational protection level on drive parameter screen
Protection level is divided into the eight-layer hierarchy as shown below.
Only the user groups belonging to the protection levels between 0 to 4 can operate the drive
parameter screen.
Protection level and Parameter access level
The access level of drive parameter is divided into three levels; Read-Only, system parame-
ter and user parameter. These levels are correspondent to the protection levels as shown
below.
Symbol
Meanings
po
Modification can not make the parameter effective. To enable the modified
parameter, you must execute the NCK-Reset. Alternatively, cut off and then turn
on the drive power supply.
im
The modified parameter becomes effective just after modification. You need not
cut off and then turn on the drive power supply.
Drive parameter
screen operation
permitted/
unpermitted
Protection
level
Requirements
User group
Operation permitted
0
System password
YSNC
1
MTB password
Tool machine manufacturer
2
Maintenance password
Setup/Service person
3
User password
Privilege user
4
Key switch position 3
Programmer
Operation
unpermitted
5
Key switch position 2
Authorized operator
6
Key switch position 1
Trained and experienced operator
7
Key switch position 0
Operator with medium technique
(NC Start/Stop, Panel operation)
Parameter indication
Parameter rewrite
Parameter access
level
System
parameter
User
parameter
Read-Only
System
parameter
User
parameter
Protection
level
0
Indication
Indication
Unrewritable
Rewritable
Rewritable
1
to
3
No indication Indication
Unrewritable
Unrewritable
Rewritable
4
No indication Indication
Unrewritable
Unrewritable
Unrewritable
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...