![YASKAWA SIEMENS CNC Series Скачать руководство пользователя страница 306](http://html2.mh-extra.com/html/yaskawa-siemens/cnc-series/cnc-series_maintenance-manual-serviceman-handbook_3193899306.webp)
Drive set-up procedure
14.3.19 Skip Function
14-96
14.3.19 Skip Function
To use the skip function for latching the sensor position by using external sensors, set the
following machine data.
SGDK servo drive has two low-active probe inputs.
CNC side setting
• MD13200 MEAS_PROBE_LOW_ACTIVE [0]
Meaning:
Low/high-active of probe 1
Setting value: 0---high-active (positive)
1---low-active (negative)
For SGDK servo drive, always set "1".
• MD13200 MEAS_PROBE_LOW_ACTIVE [1]
Meaning:
Probe 2 detection polarity
Setting value: 0---positive
1---negative
For SGDK servo drives, always set "1".
• MD13210 MEAS_TYPE
Meaning:
Skip mode selection
Setting value: When latching on SGDK servo drives, always specify "1".
Servo drive setting
For servo drives, there is no particular settings for the skip function.
As described above, for servo drives, since the polarity of skip input/output signal is low
active, be careful to set the machine data correctly. If the setting is incorrect, the polarity of
the I/O signal shown below is reversely set.
I/O signal
• DB10DBX107. 0
Meaning:
State of probe 1
Setting value: 0 -> 1 - Probe 1 ON
1 -> 0 - Probe 1 OFF
• DB10DBX107. 1
Meaning:
State of probe 2
Setting value: 0 -> 1 - Probe 2 ON
1 -> 0 - Probe 2 OFF
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...