Safety precautions
xv
■
Installing
• Store the product in an indoor clean place satisfying the environmental
requirements.
Otherwise damage could result.
The environmental requirements:
• Ambient temperature: -20 to +60
℃
• Relative humidity: 10 to 90%
• Altitude: 1000 m or lower
• Install the product such that its air intake or discharge opening is not
blocked by a wall or other objects and that foreign matter would not get
into the opening.
Otherwise a fire or damage could result.
• When installing, take care not to subject the product to a strong shock.
Otherwise damage could result.
• The electric power supplied to the product must be sufficient satisfying its
power requirements.
Otherwise malfunction could result.
• The power requirements of the 24 VDC external power supply unit supply-
ing input/output contacts depend on the number of the contacts they sup-
ply.
If necessary to provide enough power, install an additional external power supply
unit.
• The motors have their flanges and shaft ends coated with rustproof agent.
Remove the agent with a cloth before installing the motors.
• When coupling a motor with a machine, well align the motor with the
machine.
Failing to do so could cause vibration, resulting in injury or damage.
MANDATORY
CAUTION
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...