12.2.9 Setting the password (setting for write prohibit)
12-30
7. Press the [UP] or [DOWN] key to adjust the offset. You must observe the torque refer-
ence monitor signal carefully during the adjustment.
8. After completing the adjustment of U-phase (Cu1_0) and V-phase (Cu1_0) current off-
set, press the [DATA/ENTER] key to return to the auxiliary function execution mode
display.
This completes the motor current detection signal offset manual adjustment.
12.2.9 Setting the password (setting for write prohibit)
This password setting is the function to prevent the user constant form being rewritten care-
lessly.
When setting the password, the user constant which is prohibited to write is a part of the
constants beginning with Pn
□□□
or Fn
□□□
.
The setting value for passwords are followings.
• "0000" ••••• Writable (cancel of write prohibit)
• "0001" ••••• Write prohibit
(The user constant can not be written when and after the power source is
turned on next time.)
To set the password, use the following procedure.
1. On the axis selection mode, select the axis you want to operate.
2. Press the [DSPL/SET] key and select the auxiliary function execution mode.
3. Select the user constant Fn010. Press the [LEFT] or [RIGHT] key to select the setting
digit. Press the [UP] or [DOWN] key until the value you want to set is displayed.
4. Press the [DATA/SET] key and the indication will display as below.
Data setting changed.
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...