![YASKAWA SIEMENS CNC Series Скачать руководство пользователя страница 365](http://html2.mh-extra.com/html/yaskawa-siemens/cnc-series/cnc-series_maintenance-manual-serviceman-handbook_3193899365.webp)
Drive data list
A.4 List of parameters common to all drives
A-22
Note: Such values are invalid that are displayed for parameters not being used.
1037
0
0xffff
−
ENC_CONFIG_DIRECT
Direct encoder type
bit3 0: Incremental
1: Absolute
bit4 0: Rotally
1: Linear
1038
0
0xffff
−
ENC_MOTOR_SERIAL
NO_LOW
Direct encoder serial number
(LOW)
Not used
1039
0
0xffff
−
ENC_MOTOR_SERIAL
NO_HIGH
Direct encoder serial number
(HIGH)
Not used
1042
0
11
−
RESOLUTION_G1_XIS
T1
Motor encoder resolution
magnification 1 (power of 2)
Changes MD31025[0] to a
power of 2
1043
0
11
−
RESOLUTION_G1_XIS
T2
Motor encoder resolution
magnification 2 (power of 2)
Changes MD31025[0] to a
power of 2
1044
0
11
−
RESOLUTION_G2_XIS
T1
Direct encoder resolution
magnification 1 (power of 2)
Changes MD31025[1] to a
power of 2
1045
0
11
−
RESOLUTION_G2_XIS
T2
Direct encoder resolution
magnification 2 (power of 2)
Changes MD31025[1] to a
power of 2
1102
0
0xffff
−
MOTOR_CODE
Motor type
Servo-axis=1,
Spindle=1001
1401
-100000
100000
U/min
MOTOR_MAX_SPEED
Max. motor speed
Max. number of rated
motor revolutions
1405
100
110
%
MOTOR_SPEED_LIMIT
Allowable max. speed or
number of revolutions
Fixed to 120%
1711
-100000
100000
m/min
SPEED_LSB
Speed resolution
MD880/Ox40000000
1783
0
0xffff
−
PARAM_DATA_RX_PR
OFIBUS
Parameter data
1784
0
0xffff
−
CONFIG_DATA_RX_PR
OFIBUS
Configuration data
1785
0
0xffff
−
LIFESIGN_DIAGNOSIS
_PROFIBUS
Life sign error counter
1786
0
0xffff
−
PKW_DATA_RX_PROFI
BUS
PKW receiving data
Not used
1787
0
0xffff
−
PKW_DATA_TX_PROFI
BUS
PKW transmission data
Not used
1788
0
0xffff
−
PZD_DATA_RX_PROFI
BUS
Cyclically receiving data
1789
0
0xffff
−
PZD_DATA_TX_PROFI
BUS
Cyclic transmission data
1794
0
999999
−
OPTMOD_BOOTCODE
_VERSION
Loader version for optional
module
1795
0
999999
−
OPTMOD_FIRMWARE_
VERSION
Optional module software
version
1799
0
999999
−
FIRMWARE_VERSION
ACC file version
See Section 14.1.9
2401
-100000
100000
U/min
MOTOR_MAX_SPEED_
2ND_MOTOR
2nd motor max. speed
To be used for controlling
Spindle-combined C axis
when motor speed is
different.
2405
100
110
%
MOTOR_SPEED_LIMIT
_2ND_MOTOR
2nd motor allowable max.
speed
To be used for controlling
Spindle-combined C axis
when motor speed is
different.
CNC
parame
ter No.
Lower
limit
Upper
limit
Unit
Name
Description
Related MD and remark
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...