12.1 Basic operation
12-11
Procedure for changing the function selection user constant
1. Select the axis you want to change on the axis selection mode.
2. Press the [DSPL/SET] key and select the constant setting mode.
3. Select the user constant number you want to specify.
Press the [LEFT] or [RIGHT] key until the setting digit flashes. Select the value using
the [UP] or [DOWN] key. (In this case, Pn003 is selected.)
4. Press the [DATA/ENTER] key to display the current data of the user constant that you
just selected Step 3.
5. Press the [LEFT] or [RIGHT] key to select the digit number you want to set.
6. Press the [UP] or [DOWN] key to select the "value" of function setting which is defined
by the setting digit number.
To change the data, repeat the Step 5 and Step 6.
7. Press the [DATA/ENTER] key. The data is stored and flashes.
8. Press again the [DATA/ENTER] key to return to the user constant number display.
The one-digit setting of user constant Pn003 is already changed into 1.
The setting digit flashes
The setting digit flashes
The setting digit flashes
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...