14.3 Motion Control
14-83
14.3.11 Collision detection
Collision detection function detects the collision of feed axes with the disturbance observer
and enables the pullback-stop of the torque reference. You can individually specify the
torque disturbance detection level of collision detection for each of
• positioning feed
• feed other than positioning feed, and
• forced input signal.
Also, it is possible to disable the collision detection function by the external input . With this
function, a series of events from the collision detection to the stop are processed with the
servo drive. The machine data and parameters related to the collision detection function are
listed below.
For the detailed information about adjustment procedure for the collision detection function,
see the separate explanation.
Collision detection function is not available for spindles.
CNC setting
Feed axes
• MD37610 PROFIBUS_CTRL_CONFIG (For each axis)
Meaning:
CNC feed mode to the drive
This machine data permits the switching over the disturbance detection
level from the positioning feed to the other feed and vise versa.
Setting value: 0---disabled
1---enabled
You must specify 1 (enabled) when the collision detection function is
enabled.
Drive setting
• MD3063 (Pn121) GAIN_DISTURB_OBSERVER (For each servo axis)
Meaning:
Disturbance observer gain
Setting value: [Hz]
• MD3064 (Pn122) HPF_CUT_FREQ_DISTURB_OBSRVR (For each servo axis)
Meaning:
Disturbance observer high pass filter cutoff frequency
Setting value: [Hz]
• MD3066 (Pn124) LPF_CUT_FREQ_DISTURB_OBSRVR (For each servo axis)
Meaning:
Disturbance observer low pass filter cutoff frequency
Setting value: [Hz]
IMPORTANT
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...