Drive Parameter Screen
11.1.3 Operation method
11-4
11.1.3 Operation method
On the drive parameter screen, the following operations are available.
Basic operation
The basic operations are listed below;
• Use the upward/downward arrow key for one-line scroll.
• Use the right/left arrow key to transit the selected row by one.
• Use the PAGE UP/PAGE DOWN key for one-page scroll.
• Use [Drive + (F9)] key or [Drive - (F10)] key for switching the displayed target axes.
• Use [Direct selection (F11)] key for the direct switching for the target axis displayed.
• Use [Search . . . (F14)] key for searching.
• Use [Continue search (F15)] key for continuing the search.
• Use [Refresh (F16)] key to update the displayed data.
• Use [Back (F1)] key to goes back to the last page.
• Without connection to the drive, [Drive +] key, [Drive
−
] key, [Direct selection] key,
[Search . . . ]key, and [Continuous search] key are not available.
Input of setting value
The input method of setting values are categorized into 3 types; decimal number, hexadeci-
mal number and binary number.
Decimal number
Decimal number data can be input using only the numeric keys. However, if the parameter
can accept minus data, [-] key input is permitted.
Hexadecimal number
Hexadecimal number data is displayed with "H" at the end of the value. The numeric keys
from 0 to 9 and alphabetical letter keys from A to F input is available.
Binary number
Binary number data is displayed with "B" at the end of the value. Only [0] and [1] key input
is accepted. Press the [INSERT] key to switch over to the inset mode. On this mode, you can
goes to the bit position you want to modify by using [->] and [<-] keys. The input is limited
to up to 16 digits. If there are already input up to 16 digits on the insert mode, you must
delete any number using the [DEL] key.
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...