Drive set-up procedure
14.3.1 Feed Rate
14-58
• MD36200 AX_VERO_LIMIT (For each axis)
Meaning:
Speed limit (the speed which triggers alarm output)
Setting value: [mm/min] or [min
-1
]
Note: If the speed exceeds this value, the alarm 25030 is output.
For spindles, this is the speed limit in the positioning control mode.
• MD36210 CTRLOUT_LIMIT (For each axis)
Meaning:
Maximum speed reference percentage (the percentage of maximum
speed reference taking the speed reference for maximum motor speed
MD32260 (see, 14.1.7) as 100%).
Setting value: 110 [%]
Spindle
• MD35010 GEAR_STEP_CHANGE_ENABLE (For each axis)
Meaning: Gear
changing
Setting value: 0---No gear changing
1---Gear changing
• MD35100 SPIND_VERO_LIMIT (For each axis)
Meaning:
Maximum speed of spindle
Setting value:
[min
-1
]
• MD35110 GEAR_STEP_MAX_VERO [n] (For each axis)
Meaning:
Maximum speed of the nth gear
Setting value:
[min
-1
]
• MD35120 GEAR_STEP_MIN_VERO [n] (For each axis)
Meaning:
Minimum speed of the nth gear
Setting value:
[min
-1
]
• MD35130 GEAR_STEP_MAX_VERO_LIMIT [n] (For each axis)
Meaning:
Maximum speed limit of the nth gear
Setting value:
[min
-1
]
• MD35140 GEAR_STEP_MIN_VERO_LIMIT [n] (For each axis)
Meaning:
Minimum speed limit of the nth gear
Setting value:
[min
-1
]
• MD35300 SPIND_POSCNTL_VERO (For each axis)
Meaning:
Maximum speed for spindle positioning control mode
Setting values: [min
-1
]
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...