Appendix B Alarm/monitor data
A-23
Appendix B Alarm/monitor data
B.1 List of Servo unit alarms
CNC
code
Drive
code
Item
CNC
code
Drive
Description
2
0x02
EEPROM data error
97
0x61
C-phase signal detection failure
2
0x02
Flash memory error
98
0x62
C-phase signal width failure
3
0x03
Main circuit detecting element error
99
0x63
Error with pulse count per rotation when
encoder is used
3
0x03
CNV main circuit detecting element error
99
0x63
Error with pulse count per rotation when
magnetmetric sensor is used
3
0x03
Main circuit detecting element error
99
0x63
Encoder pulse count error
4
0x04
Parameter setting error
100
0x64
Position-detecting signal wire break
5
0x05
Motor/Servo capacity unmatched
101
0x65
INC signal error when encoder is used
6
0x06
DPRAM error
101
0x65
INC signal error when magnetmetric
sensor is used
16
0x10
Over current
(Short-circuit current)
102
0x66
Magnetmetric sensor signal detection
error
17
0x11
Ground fault
103
0x67
Magnetmetric sensor signal wire break.
18
0x12
Carrier frequency error
104
0x68
Orientation card unmatched
19
0x13
On-delay error
105
0x69
Winding change-over failure
20
0x14
Motor over-current
106
0x6A
Initial zero point loading error
32
0x20
Fuse blow-out
107
0x6B
Emergency stop operation failure
33
0x21
MC operation failure
113
0x71
Over-load (Momentary max. load)
34
Ox22
Converter fuse blow-out
114
0x72
Over-load (Max. continuous load)
48
0x30
Regeneration error
115
0x73
DB over-load
50
0x32
Regeneration over-load
116
0x74
Inrush current resistance over-load
50
0x32
Regeneration over-load
117
0x75
Control panel temperature rise to 60
℃
51
0x33
Main power wiring error
117
0x75
Internal cooling fan error
52
0x34
Converter regeneration over-current
118
0x76
Load error
64
0x40
Over-voltage
119
0x77
Collision
64
0x40
CNV over-voltage
121
0x79
Motor overheat
65
0x41
Low-voltage
121
0x79
Motor thermistor wire break
65
0x41
CNV low-voltage
122
0x7A
Heat sink over-heat
66
0x42
Initial charging error
122
0x7A
Fin temperature rise for more than 1
minute
67
0x43
Control circuit low-voltage
122
0x7A
Heat sink thermistor wire break
68
Ox44
Control power low-voltage
123
0x7B
Fin temperature rise for more than 1
minute
81
0x51
Over-speed (at motor)
129
0x81
PG back-up error
82
0x52
Over-speed (at machine)
130
0x82
PG sum check error
83
0x53
Excessive speed deviation
131
0x83
PG battery error
84
0x54
Over-speed (at low-speed winding motor)
132
0x84
PG absolute error
96
0x60
Tune-up incomplete when encoder is used
133
0x85
PG over-speed
96
0x60
Tune-up incomplete when magnetmetric
sensor is used
134
0x86
PG over-heat
Содержание CNC Series
Страница 1: ...Maintenance Manual Serviceman Handbook MANUAL No NCSIE SP02 19 Yaskawa Siemens CNC Series...
Страница 26: ...Part 1 Hardware...
Страница 38: ...System Configuration 1 2 3 Spindle motor designations 1 12...
Страница 58: ...Installing the control panels 2 3 5 Installing lightning surge absorbers 2 20...
Страница 62: ...Installing the motors 3 4...
Страница 84: ...Connection method 4 3 2 Setting the rotary switches on the inverters and servo units 4 22...
Страница 96: ...Part 2 Software...
Страница 102: ...Software configuration 6 6...
Страница 103: ...7 1 Chapter 7 Backup 7 1 How to archive 7 2 7 2 Network settings 7 7 7 2 1 YS 840DI settings 7 7 7 2 2 PC settings 7 14...
Страница 105: ...7 1 How to archive 7 3 3 Select the Workpieces folder 4 Click on Archive File which is one of the right side keys...
Страница 113: ...7 2 Network settings 7 11 8 Click on the radio button to the left of Specify an IP address...
Страница 121: ...7 2 Network settings 7 19...
Страница 122: ...Part 3 PLC...
Страница 154: ...Part 4 Setting up and maintenance...
Страница 160: ...Overview of System 10 1 2 Basic operation 10 6...
Страница 204: ...How to use Digital Operation 12 2 9 Setting the password setting for write prohibit 12 32...
Страница 327: ...Error and Troubleshooting 15 4...
Страница 328: ...15 1 Errors without Alarm Display and Troubleshooting 15 5...
Страница 329: ...Error and Troubleshooting 15 6...
Страница 343: ...Maintenance and Check 16 3 3 Setting up Initializing Absolute encoder 16 14...