cordless.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
11-9
HiPath Cordless Office
Power-Related Capacity Limits
Supplying power to base stations
The internal power supply unit in the respective system is the main power source for the base
stations. For more information on the various power supply options, please refer to Page 3-160.
7
32
27
23
19
14
10
8
27
22
18
13
9
5
Table 11-7
HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS3/3 Base Stations Connected to SLC16N and BS4 Base
Stations Connected to SLC16N
Number
of BS3/3s and BS4s
connected via
2xU
P0/E
to
SLC16N
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
1
64
60
56
51
47
42
2
60
56
52
47
43
39
3
57
52
48
43
39
35
4
53
48
44
40
35
31
5
49
44
40
36
31
27
6
45
40
36
32
27
23
7
41
37
32
28
23
19
8
37
33
28
24
20
15
>
When using an additional power supply (such as
), HiPath
3550 and HiPath 3500 can be expanded up to the maximum possible capacity
limit specified in Table 2-7.
Table 11-6
HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS2/2 Base Stations Connected to SLC16N
Number
of BS2/2s
On
SLC16N
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......