inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-63
Installing HiPath 3000
Installing HiPath 3800
4.2.6.6
For U.S. only: Connecting Peripherals to the Connector Panels with CHAMP
Jack
The boards should be installed in the cabinets as described in Section 4.2.5. The S30807-
Q6626-X connector panels attached to the SIVAPAC connectors on the backplane are
equipped with a CHAMP jack.
Connect the peripheral directly to the CHAMP jack in the connector panels.
Information on cable and connector assignment is provided in the board descriptions in
Chapter 3.
Figure 4-35
HiPath 3800 - Connector Panel with CHAMP Jack (for U.S. only)
7
Danger
Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
If
Then
Slot with periph-
eral card
A cable with CHAP jack should be used to connect to a main distributor
frame or external patch panel.
No assignment The backplane sections with empty board slots must be covered with filler
panels.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......