inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-29
Installing HiPath 3000
Installing HiPath 3800
Grounding the system cabinets and possible patch panels
Figure 4-13
HiPath 3800- Grounding the Systems and Patch Panels in a 19-Inch Cabinet
Patch Panel
(if present)
for example, Patch Panel
S30807-K6143-X
Potential equalization bus,
in 19" cabinet for example
HiPath 3800, BC
HiPath 3800, EC (if present)
Attach to the grill using
cable ties
Any color, except for green or
yellow to avoid confusion
Min. cross-section
≥
2.5 mm
2
To other patch panels S30807-K6143-X (if
present)
(A ground conductor is not required for the S
0
patch panel S30807-K6143-X.)
green/yellow
Min. cross-section
≥
2.5 mm
2