Installing HiPath 3000
P31003-H3560-S403-54-7620, 09/05
4-130
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
inst_h3.fm
Installing HiPath 3750, HiPath 3700
4.3.4.1
Selecting the Installation Site
The installation site is generally determined by the 19-inch cabinet already installed.
The environmental conditions specified in the system data chapter should also be taken into
consideration in this case (Section 2.11).
Information on the design of the HiPath 3700 can be found in Section 2.2.2.5.
4.3.4.1.1
For U.S. only: AC outlet
An AC connection is required for each cabinet. The AC connection must fulfill the requirements
specified in Table 4-14.
The system must be properly grounded before startup (see description in Section 4.3.4.5).
4.3.4.2
Unpacking the Components
Procedure
Table 4-14
Electrical Connection Values (for U.S. only)
Nominal
voltage
Nominal voltage range
Nominal Frequency
Range
Wall Outlet Configura-
tions
from to
from to
120 V AC/
60 Hz
110 V AC
130 V AC
47 Hz
63 Hz
NEMA 5-15, 2-pin, 3-
wire, earth
Step
Activity
1.
Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2.
Determine whether any damage has occurred during transport and report it to the
proper departments.
3.
Dispose of the packing materials properly.
7
Caution
Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......