boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-87
Boards for HiPath 3000
Central Boards
Front and rear views of the UPSM (S30122-K5950-A100)
Figure 3-36
Front and Rear Views of the UPSM (S30122-K5950-A100)
REAR
VIEW
FRONT
VIEW
LED
Warning:
High Voltage
Connector for system supply
voltages
AC outlet
OFF
ON
Modular ring genera-
tor
ON/OFF switch for
secondary operating
voltages (system sup-
ply voltages)
Overload protection for battery
mode
1
4
3
2
DIP switches
(for example 25 Hz)
Off
On
Modular ring generator
Ring frequency selector:
DIP switch settings
(S4 = used for factory testing)
1
2
3
4
Frequency
On Off Off
20 Hz
Off On Off
25 Hz
Off Off On 50
Hz
Connector for battery pack or
battery cabinet
Only plug in or unplug the
connector when in de-ener-
gized state (switch = OFF).