inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-159
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
The figures below show the PCM segments (64 time-division multiplex channels each) for the
different HiPath 3750 and HiPath 3700 system configurations.
Single-cabinet system: PCM segments
7
Caution
The following board assignment rules must be observed to ensure that the system
works properly and without blocking:
●
SLC16N
–
Maximum SLC16N per PCM segment. The SLC16N should be configured
alone on the PCM segment, where possible.
–
Note the following information on the subject of multi-SLCs: “SLC16N board
distribution in HiPath 3750 and HiPath 3700 cabinets” on page 3-156.
●
IVML8, IVML24
(see Section 3.3.6)
–
A maximum of one IVML8 or IVML24 per system.
–
Then install them in the slot beside the power supply in the basic cabinet or
the expansion cabinets.
–
No SLC16N may be inserted in the PCM segment of the IVML8/IVML24.
–
No SLMO24 may be inserted in the PCM segment of the IVML24.
–
If a TMS2 is configured on the PCM segment of the IVML24, only a board
with a maximum of 8 ports may be inserted in the free slot.
●
SLMO24
A maximum of two SLMO24s per PCM segment; the number of connected sta-
tions (hosts (master)
and
clients (slaves)) may not be more than 64.
Figure 4-90
PCM Segments for a One-Cabinet System
C
B
C
P
R
0
2
0
3
0
4
0
8
U
P
S
M
0
5
0
6
0
7
“8-slot” cabinets
BC
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......